The Allen Building is comprised
of offices. The primary HVAC for this building is one AHU
with multiple zones. There is a chiller and Hot Water converter.
There is also a Hawkeye Power Meter for measuring the KW for this
building. |
 |
Bolling Hall is a dormitory. There
is Heat Only in this building from pneumatic (air) control valves
to each zone and a Hawkeye Power Meter for measuring the KW for
this building. |
 |
Buchanan has no DDC controls. |
 |
International Studies (Cook)
Hall is an Academic Building. There is a chiller with Ice
storage capacity, converter for Hot Water, 5 AHU's with VAV boxes
in classrooms and a Hawkeye Power Meter for measuring the KW for
this building. |
 |
Curie Hall is an Academic Building.
There is chill water available from the Chiller at Reed Hall.
There are FCU's in each classroom on all four floors with 2 Make-Up
AHU's on the roof. |
 |
Dalton Hall has dining areas and the bookstore.
There are 2 chillers, cooling tower, hot water converter, 6 AHU's,
2 Make-Up AHU's, VAV's, and Exhaust Fans in this building. |
 |
Davis Hall is an academic building.
There is a chiller, hot water converter, 6 AHU's, and FCU's in this
building. |
 |
Dedmon Center is a sports
complex with an arena, pool, exercise areas, weight rooms, locker
rooms and offices. The roof of the arena is kept in place
with the use of 6 AHU's. They control the air pressure to
ensure that the roof stays in place. There are 9 AHU's for
the pool areas and offices, FCU's in some offices and a Boiler for
Hot Water . |
 |
Draper Hall is a dormitory. There
is Heat Only in this building from pneumatic (air) control valves
to each zone and a Hawkeye Power Meter for measuring the KW for
this building. |
 |
Fairfax Hall has classrooms and offices.
There is heat only in this building from Zone control pneumatic
valves which modulate for steam flow to radiators. |
 |
Floyd Hall is a dormitory.
There are 3 Energy Recovery Units for Make-Up air on the roof, a
chiller, hot water converter and FCU's in each dorm room.
There are individual room thermostats for control within each room.
The dial adjustment on the thermostat will increase/decrease the
set point for the room. The rooms also have window sensors
and occupancy sensors to determine when the windows are open or
the room is un-occupied. The FCU will shut down and only operate
at un-occupied set points if these conditions occur. |
 |
Heth Hall is an administration building.
There is a bowling alley, billiards rooms and other activity based
rooms. There is a chiller, hw converters in basement and attic,
9 AHU's, VAV's, and FCU's in this building. Some of the FCU's
are still pneumatic controls. |
 |
Ingles Hall is a dormitory.
There is a chiller, hw converter, 1 AHU for Make-Up air and FCU's
in each room. The dial adjustment on the thermostat will increase/decrease
the set point for the room. The FCU's run at all times to
keep the space at set point. |
 |
Jefferson Hall is a dormitory
with Networking offices in the basement. The Networking offices
have a separate condensing unit for cooling purposes. The
dormitory itself is Heat Only in this building from pneumatic (air)
control valves to each zone and a Hawkeye Power Meter for measuring
the KW for this building. |
 |
Lucas Hall has no DDC controls. |
 |
Madison Hall is a dormitory. There
is Heat Only in this building from pneumatic (air) control valves
to each zone and a Hawkeye Power Meter for measuring the KW for
this building. |
 |
Martin Hall is an administration building.
There is a chiller, 2 converters (Martin/Preston), 4 Existing AHU's,
2 AHU's, 2 Make-Up air AHU's, FCU's and VAV's. Parts of the
building still have dual temperature control. |
 |
McConnell Hall - Library. There is
a chiller, hot water converter, 5 AHU's, FCU's, VAV's and a Make-Up
Air unit. Some of the controls are still pneumatic. |
 |
McGuffey Hall is an academic building.
There is a chiller with ice storage capacity, 7 AHU'S and FCU's
in this building. |
 |
Moffett Hall is a dormitory. There
is Heat Only in this building from pneumatic (air) control valves
to each zone and a Hawkeye Power Meter for measuring the KW for
this building.
|
 |
Muse Hall is partially dormitories,
dining areas, offices and classrooms. The majority of the
building is Heat Only in this building from pneumatic (air) control
valves to each zone and a Hawkeye Power Meter for measuring the
KW for this building. There is a chiller and cooling tower
for the dining areas, classrooms and offices. |
 |
Norwood Hall is a dormitory. There
is a chiller and hot water converter for this building. This
is also a Dual Temperature system. |
 |
Peery Hall is a dormitory
that was renovated in 2003. There are 3 Energy Recovery Units for
Make-Up air on the roof, a chiller, hot water converter and FCU's
in each dorm room. There are individual room thermostats for
control within each room. The dial adjustment on the thermostat
will increase/decrease the set point for the room. The rooms
also have window sensors and occupancy sensors to determine when
the windows are open or the room is un-occupied. The FCU will
shut down and only operate at un-occupied set points if these conditions
occur. |
 |
Peters Hall was renovated in 2003.
There is a chiller, 4 AHU's, VAV's with re-heat valves and hot water
converters for this building. AHU-4 serves the Gym only.
The other AHU's provide conditioned air to the VAV's. |
 |
Pocahontas Hall is a dormitory.
There is Heat Only in this building from pneumatic (air) control
valves to each zone and a Hawkeye Power Meter for measuring the
KW for this building. |
 |
Porterfield Hall is an academic
building. There are 2 chillers w/cooling tower, hot water
converter, 8 AHU's and VAV's in this building. There are still
some pneumatic controls for the multi-zone units and summer/winter
changeover. Parts of this building are Dual Temperature system
controls. |
 |
Powell Hall is an academic
building. There are 2 chillers w/cooling tower, hot water
converter, steam heat to radiation type heaters, 4 AHU's and FCU's
in this building. The first floor is still mostly pneumatic
controls while the second floor has been renovated to DDC control. |
 |
Preston Hall is an academic building.
There are 6 AHU's, 1 Chiller w/cooling tower, hot water converter,
VAV's and FCU's in this building. There are still some pneumatic
controls on the older AHU's. |
 |
Reed Hall is an academic building.
There are 3 chillers, 1 AHU, VAV's, 4 Phoenix Hoods, hot water converter
and FCU's in this building. |
 |
Russell Hall is an academic
building. The Radford University Police Department is located
in this building. The campus Fire Alarm system has terminals
in the Police Department. There is a chiller w/cooling tower,
1 AHU and FCU's in this building. There are still some pneumatic
controls in this building. |
 |
Stuart Hall is a dormitory. It is
currently under renovation to install controls similar to Floyd
and Peery Halls. |
 |
Trinkle Hall is a dormitory. There is Heat
Only in this building from pneumatic (air) control valves to each
zone and a Hawkeye Power Meter for measuring the KW for this building. |
 |
Tyler Hall is a dormitory with offices in
the ground floor. This building has a chiller w/cooling tower,
3 AHU's and FCU's. This building has a Dual Temperature System. |
 |
University Services Center is a support
building. This building has a chiller, boiler, 9 AHU's, 1
H&V (Heat and Ventilation), and 1 HRU (Heat Recovery Unit). |
 |
Waldron College is an academic building.
This building has a chiller w/Ice storage capacity, hot water converter,
2 AHU's and VAV's. |
 |
Walker Hall is an academic building.
There are 3 chillers, hot water converter, 8 AHU's, FCU's and VAV's
in this building. |
 |
Washington Hall is a dormitory. There is
Heat Only in this building from pneumatic (air) control valves to
each zone and a Hawkeye Power Meter for measuring the KW for this
building. |
 |
Whitt Hall is a academic building.
There is a chiller, hot water converter, 2 AHU's and FCU's in this
building. The majority of this building is still pneumatic
controls. |
 |
Young Hall is an academic building.
There is a chiller, hot water converter, 1 AHU and FCU's in this
building. The controls are Dual Temperature for this building.
|